Scope of Application The charger is used to supplement the maintenance of lifeboat battery.
Work Instructions Red(red) : Alarm indicates that there is no output alarm when there is open circuit - reverse circuit - short circuit. Yellow: indicates that the battery is automatically charged when the voltage is lower than 13.3V. Creen(green) : The charging indicator stops automatically when the battery voltage reaches 14.4V.
Technical Parameters Operating voltage 42V/AC 50/60HZ Full voltage 14.4V/DC Supplementary voltage 13.3V/DC Charging current ≤5(2 channels) Size 243×134×80 Weight 5kg Protection is IP56 Ambient temperature -25℃ ~ 55℃
How to Use Wiring sequence: Battery first, then 42V/AC/ power supply.
Fault Analysis Precautions! This product can only be used as the supplementary maintenance of the battery, not the initial charge of the battery!